Clinipath Mini Particle Counter


The Clinipath Mini Particle Counter is a very precise means of checking leaks in negative air machines as well as any other high efficiency particle arresting (HEPA) filtration system.
The test that is traditionally done on negative air machines is an industry standard efficiency test that requires upstream and downstream measurement of a generated aerosol (usually DOP) having an average particle size of 0.3 microns. The efficiency usually must meet or exceed 99.97% to pass this test. There are instruments on the market that are specifically designed to perform that test that consist of an aerosol generator and a photometer to measure concentration in milligrams per cubic meter. The Clinipath Mini particle counter is a particle counter, rather than a photometer. The difference is that a particle counter counts single particles and a photometer measures the density of a cloud of particle. Photometers cannot “see” single particles. The Mini particle counter cannot effectively perform the same efficiency test as above, however, it can be used to perform a leak test that is far more stringent. A negative air machine that passes the DOP efficiency test will often exhibit leaks that can be precisely located and eliminated using the Clinipath Mini particle counter. Often, these leaks are found around the filter gaskets, not the filter itself. The leaks may involve thousands of ultrafine particles per cubic centimeter and yet be invisible to a photometer since they are too small to be detected.

HEPA filters are typically certified at 99.97% efficient when manufactured. After that, there are only two things that can happen to the filter.

1. It can load up with particulates and eventually clog.
2. It can develop leaks due to age or physical damage.

In the case of loading, the filter will become more and more efficient over time, but incur higher pressure drop. This can be tested with a differential pressure gauge such as a Magnehelic. Since filters naturally become more and more efficient during use, that leaves leaks as the primary concern. In other words, the only thing that can cause exposure to particle contaminants when using a previously certified HEPA filter is that it can develop leaks (of course, the gaskets around the filter can also leak).

  • Sizing sensitivities from 0.3 to 5.0 µm
  • Simultaneously sizes and counts particles in 3 fixed channels
  • Sample flow rate of 0.1 ft.3/min. (2.83 L/min.)
  • Quiet pump, smart flow control
  • Power supply for dedicated use, batteries for mobile use
  • Stores up to 10,000 samples
  • Five different sampling modes
  • Data output via RS-232 or RS-485
  • Data download software INCLUDED
  • One year warranty
  • External printer optional
  • Four standard AA-sized, high capacity, quick change, rechargeable NiMH batteries